Regular inspection of electric basket

1, the Suspended Platform work after a certain period of time, should be checked regularly, and make records. Broken wires, loose strands, bending, conduct a comprehensive inspection, such as reach standards, should be replaced with scrap.
2, each two months after a comprehensive inspection shall be carried out in accordance with the requirements of the security check, and check the electromagnetic brake lining wear condition and cable damage.
3, every six months to a test to calibrate the safety lock, if users do not have conditions should be sent when the manufacturer test calibration.
4, safety lock after each use, should add the rust-proof, remain flexible motion.
5, hoist transmission device for the first time use after three months must replace lubricating oil, a lubricating oil a month later, once every six months in lubricating oil.
6, safety lock activity place a lubricating oil per month.
7, electrical wiring, electrical components and wires contact must be kept dry, clean, can not have oil fouling.
8, in safety, daily, regular examination and operation process, finding fault, wear, or abnormal, should immediately stop using, by professional personnel for maintenance, forbidden Suspended Platform "being" is used.
9, each mechanical component, to scrap parts, standard, shall be discarded and replaced.
10, to set up the Suspended Platform equipment files, keep Suspended Platform normal intact.